Ürün No. 44515
WP Flex 1K
Tek bileşenli esnek su yalıtım şerbeti

Ürün varyantları
İndirilebilir Dökümanlar
Teknik Özellikler
Uygulama Alanları
- Waterproofing in new buildings
- Subsequent exterior waterproofing in existing buildings
- Horizontal waterproofing in and underneath walls
- Waterproofing of plinths and base points
- Waterproofing in a bond
- Container sealing up to max. 3 m filling height
Özellikler
- Very low emissions (GEV-EMICODE EC 1Plus)
- Flexible
- Good adhesion to the substrate
- Can be applied as a grout and a filler
- Water pressure tight according to DIN EN 14891
- Substrate requirements: The substrate must be clean, dry, flat and capable of bearing a load, and free of dust, oil, grease and release agents. Roughen non-mineral and pore-free substrates. Absorbent mineral substrates may be slightly damp.
- Preparations: Remove projecting seams and mortar remains. Break off or chamfer corners and edges. Reinforce transitions/connections/joints to and on non-mineral substrates/components with joint tape (Tape VF). Optionally, use a suitable mortar to produce a sealing cove. Seal off indentations > 5 mm using a suitable filling knife. If necessary, provide damp proofing. Roughen the surface of plastic pipes; clean and, if necessary, sand metal pipes. W1-E: seal pipe penetrations by using the product to form a cove around them. Prime absorbent mineral substrates with Kiesol MB. Apply a scratch coat of the product to act as a contact layer and reduce blistering. Allow the contact layer to dry completely before continuing with subsequent work steps.

- Vertical surface waterproofing Apply the product in two layers on the previously prepared substrate. Horizontal surface waterproofing Apply the product in two layers on the previously prepared substrate. Apply the second layer once the first can no longer be damaged. Apply suitable protective layers once the waterproofing is completely dry. At the edges, the waterproofing layer is applied up to the upper edge of the floor or up to the horizontal barrier. Connection details/building element joints Bridge corner and connection joints with the Tape VF joint tape system. Apply the product, embed Tape VF over the entire surface, ensuring that there are no bubbles or creases.
- In the case of liquid-applied waterproofing materials, direct sunlight and/or wind exposure can cause accelerated skin formation and accompanying blistering. In case of damp behind the surface, use rear damp protection / apply an intermediate seal coat of rigid mineral waterproofing slurry. Protect the fresh waterproofing layer from rain, direct sunlight, frost and condensation water. Protect the dry waterproofing material from mechanical damage. Add a further load-distributing layer if using the product for waterproofing under raised floor supports. Laying ceramic tiles Lay tiles once the waterproofing layer is completely dry.
- Mixing tool, wide brush, paintbrush, smoothing trowel, slurry broom, spreader Clean tools with water while the material is still fresh.

- In unopened original containers stored cool, dry and protected from frost for 1 year.
- Approx. 1.3 kg/m²/mm
- Apply to a large enough trial area to determine the precise amount required.
- Layer thicknesses and application rate for use in interior and exterior areas
- The mixing water must be of drinking water quality. May contain traces of pyrite (iron sulphide). Low chromate content in accordance with Directive 2003/53/EC. The characteristic data of the product were calculated under laboratory conditions at 20°C and 65% relative humidity. Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately. The relevant test certificates must be observed when planning and carrying out work. Always set up a trial area/trial areas first.
- Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
- For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.